Run 100866 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v25
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-30T12:40:45+00:00
App 53
Duration 360.371 s
Run quality COMPLETE

Primary result

Signed field change: -2.7 nT (-0.006%)

Measure Value N / window
Reference field 48.098999 µT 1500 / 0–30 s
Outcome field 48.096276 µT 3000 / 240–300 s
Absolute change 2.7 nT same windows
Angular change 0.073° same windows

Summary: CONTROL; -2.7 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9974 Hz effective over N=18010 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.0005532 µT/s (0.199245 µT over 0.0–360.2 s, N=18010)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
330–340 s 10 s 421.5 nT 5.91 500
331–341 s 10 s 417.3 nT 5.85 500
332–342 s 10 s 415.3 nT 5.82 500
333–343 s 10 s 412.9 nT 5.79 500
337–347 s 10 s 409.2 nT 5.74 500
334–344 s 10 s 405.0 nT 5.68 500
337–357 s 20 s 404.3 nT 5.67 1000
335–345 s 10 s 403.4 nT 5.65 500
330–350 s 20 s 403.3 nT 5.65 1000
336–346 s 10 s 402.6 nT 5.64 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.