Run 100860 — ATTENTION

Practitioner unknown
Condition ATTENTION
Analyzer maglab-analyzer v25
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-30T12:34:47+00:00
App 53
Duration 360.511 s
Run quality COMPLETE

Primary result

Signed field change: +153.1 nT (+0.320%)

Measure Value N / window
Reference field 47.886131 µT 1496 / 0–30 s
Outcome field 48.039225 µT 3000 / 240–300 s
Absolute change 153.1 nT same windows
Angular change 0.183° same windows

Summary: ATTENTION; +153.1 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9881 Hz effective over N=17996 samples, 2 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.0007182 µT/s (0.258542 µT over 0.0–360.0 s, N=17996)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
328–338 s 10 s 282.9 nT 13.98 500
327–337 s 10 s 282.6 nT 13.96 500
325–335 s 10 s 274.2 nT 13.55 500
329–339 s 10 s 274.0 nT 13.54 500
326–336 s 10 s 271.0 nT 13.39 500
324–334 s 10 s 267.0 nT 13.19 500
322–332 s 10 s 262.6 nT 12.98 500
317–337 s 20 s 261.0 nT 12.90 1000
323–333 s 10 s 260.7 nT 12.88 500
330–340 s 10 s 260.1 nT 12.85 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.