Run 100854 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v25
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-30T12:21:39+00:00
App 53
Duration 360.412 s
Run quality COMPLETE

Primary result

Signed field change: +378.0 nT (+0.248%)

Measure Value N / window
Reference field 152.173980 µT 1499 / 0–30 s
Outcome field 152.551964 µT 3000 / 240–300 s
Absolute change 378.0 nT same windows
Angular change 0.141° same windows

Summary: CONTROL; +378.0 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9955 Hz effective over N=18007 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00110538 µT/s (0.398103 µT over 0.0–360.2 s, N=18007)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
128–138 s 10 s 525.2 nT 5.67 500
127–137 s 10 s 519.1 nT 5.61 500
129–139 s 10 s 517.1 nT 5.59 500
144–154 s 10 s 516.5 nT 5.58 500
131–141 s 10 s 515.5 nT 5.57 500
145–155 s 10 s 513.8 nT 5.55 500
130–140 s 10 s 512.8 nT 5.54 500
147–157 s 10 s 504.3 nT 5.45 500
127–157 s 30 s 499.7 nT 5.40 1500
144–164 s 20 s 499.6 nT 5.40 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.