Run 100846 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v25
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-30T11:52:29+00:00
App 53
Duration 374.109 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +581.7 nT (+1.176%)

Measure Value N / window
Reference field 49.447895 µT 1500 / 0–30 s
Outcome field 50.029601 µT 3000 / 240–300 s
Absolute change 581.7 nT same windows
Angular change 0.403° same windows

Continuous ambient comparison

Compared with 109 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -14.4 nT.

Summary: CONTROL; +581.7 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=18008 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00230923 µT/s (0.831646 µT over 0.0–360.1 s, N=18008)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
314–324 s 10 s 727.6 nT 11.54 500
292–302 s 10 s 727.5 nT 11.54 500
289–299 s 10 s 726.2 nT 11.52 500
315–325 s 10 s 725.7 nT 11.51 500
316–326 s 10 s 724.5 nT 11.49 500
291–301 s 10 s 723.2 nT 11.47 500
288–298 s 10 s 719.7 nT 11.42 500
317–327 s 10 s 719.0 nT 11.41 500
322–332 s 10 s 717.1 nT 11.38 500
290–300 s 10 s 716.1 nT 11.36 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.