Run 100813 — ATTENTION

Practitioner unknown
Condition ATTENTION
Analyzer maglab-analyzer v24
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-29T04:26:28+00:00
App 38
Duration 300.365 s
Run quality COMPLETE

Primary result

Signed field change: -633.1 nT (-1.155%)

Measure Value N / window
Reference field 54.802667 µT 1500 / 0–30 s
Outcome field 54.169554 µT 3000 / 240–300 s
Absolute change 633.1 nT same windows
Angular change 0.797° same windows

Continuous ambient comparison

Compared with 34 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +55.7 nT.

Summary: ATTENTION; -633.1 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15003 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00241445 µT/s (-0.724432 µT over 0.0–300.0 s, N=15003)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
284–294 s 10 s -787.4 nT 13.93 501
282–292 s 10 s -781.7 nT 13.83 499
289–299 s 10 s -780.8 nT 13.81 501
290–300 s 10 s -773.7 nT 13.69 500
286–296 s 10 s -772.2 nT 13.66 499
281–291 s 10 s -770.9 nT 13.64 500
277–287 s 10 s -770.8 nT 13.64 500
280–300 s 20 s -770.7 nT 13.63 1000
285–295 s 10 s -769.8 nT 13.62 501
277–297 s 20 s -769.1 nT 13.61 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.