Run 100811 — ATTENTION

Practitioner unknown
Condition ATTENTION
Analyzer maglab-analyzer v24
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-29T04:10:29+00:00
App 38
Duration 300.323 s
Run quality COMPLETE

Primary result

Signed field change: -826.4 nT (-1.509%)

Measure Value N / window
Reference field 54.780890 µT 1500 / 0–30 s
Outcome field 53.954517 µT 3000 / 240–300 s
Absolute change 826.4 nT same windows
Angular change 0.785° same windows

Continuous ambient comparison

Compared with 31 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +93.8 nT.

Summary: ATTENTION; -826.4 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15001 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00304925 µT/s (-0.914775 µT over 0.0–300.0 s, N=15001)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
130–140 s 10 s -1157.5 nT 7.18 500
129–139 s 10 s -1157.2 nT 7.18 501
128–138 s 10 s -1132.2 nT 7.02 501
127–137 s 10 s -1056.7 nT 6.55 501
287–297 s 10 s -987.2 nT 6.12 500
289–299 s 10 s -983.9 nT 6.10 500
290–300 s 10 s -980.7 nT 6.08 500
288–298 s 10 s -975.7 nT 6.05 500
131–141 s 10 s -968.6 nT 6.01 499
284–294 s 10 s -959.7 nT 5.95 500

Files

Interpretation boundary