Run 100802 — ATTENTION

Practitioner unknown
Condition ATTENTION
Analyzer maglab-analyzer v24
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-29T02:49:26+00:00
App 38
Duration 300.300 s
Run quality COMPLETE

Primary result

Signed field change: -387.0 nT (-0.692%)

Measure Value N / window
Reference field 55.924330 µT 1501 / 0–30 s
Outcome field 55.537282 µT 3000 / 240–300 s
Absolute change 387.0 nT same windows
Angular change 0.347° same windows

Summary: ATTENTION; -387.0 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15004 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00143978 µT/s (-0.432022 µT over 0.0–300.1 s, N=15004)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
290–300 s 10 s -481.0 nT 19.33 500
287–297 s 10 s -479.9 nT 19.28 500
289–299 s 10 s -473.2 nT 19.02 499
288–298 s 10 s -471.7 nT 18.96 500
285–295 s 10 s -453.4 nT 18.22 500
286–296 s 10 s -452.7 nT 18.19 500
280–300 s 20 s -450.7 nT 18.11 1000
279–299 s 20 s -442.2 nT 17.77 999
278–298 s 20 s -440.5 nT 17.70 1000
284–294 s 10 s -439.7 nT 17.67 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.