| Practitioner | unknown |
| Condition | CONTROL |
| Analyzer | maglab-analyzer v24 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-29T02:21:20+00:00 |
| App | 38 |
| Duration | 300.251 s |
| Run quality | COMPLETE |
Signed field change: -145.1 nT (-0.258%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 56.125509 µT | 1501 / 0–30 s |
| Outcome field | 55.980438 µT | 3000 / 240–300 s |
| Absolute change | 145.1 nT | same windows |
| Angular change | 0.226° | same windows |
Summary: CONTROL; -145.1 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15002 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.0006126 µT/s (-0.183787 µT over 0.0–300.0 s, N=15002) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 278–288 s | 10 s | -224.7 nT | 8.13 | 500 |
| 276–286 s | 10 s | -220.8 nT | 8.00 | 500 |
| 280–290 s | 10 s | -220.7 nT | 7.99 | 500 |
| 277–287 s | 10 s | -213.1 nT | 7.72 | 500 |
| 279–289 s | 10 s | -212.0 nT | 7.67 | 500 |
| 282–292 s | 10 s | -207.2 nT | 7.50 | 500 |
| 283–293 s | 10 s | -204.8 nT | 7.42 | 500 |
| 280–300 s | 20 s | -204.5 nT | 7.40 | 1000 |
| 277–297 s | 20 s | -202.9 nT | 7.34 | 1000 |
| 281–291 s | 10 s | -202.4 nT | 7.33 | 500 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.