Run 100799 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v24
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-29T02:21:20+00:00
App 38
Duration 300.251 s
Run quality COMPLETE

Primary result

Signed field change: -145.1 nT (-0.258%)

Measure Value N / window
Reference field 56.125509 µT 1501 / 0–30 s
Outcome field 55.980438 µT 3000 / 240–300 s
Absolute change 145.1 nT same windows
Angular change 0.226° same windows

Summary: CONTROL; -145.1 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15002 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.0006126 µT/s (-0.183787 µT over 0.0–300.0 s, N=15002)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
278–288 s 10 s -224.7 nT 8.13 500
276–286 s 10 s -220.8 nT 8.00 500
280–290 s 10 s -220.7 nT 7.99 500
277–287 s 10 s -213.1 nT 7.72 500
279–289 s 10 s -212.0 nT 7.67 500
282–292 s 10 s -207.2 nT 7.50 500
283–293 s 10 s -204.8 nT 7.42 500
280–300 s 20 s -204.5 nT 7.40 1000
277–297 s 20 s -202.9 nT 7.34 1000
281–291 s 10 s -202.4 nT 7.33 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.