| Practitioner | unknown |
| Condition | CONTROL |
| Analyzer | maglab-analyzer v24 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-29T00:05:56+00:00 |
| App | 38 |
| Duration | 300.279 s |
| Run quality | COMPLETE |
Signed field change: -124.3 nT (-0.222%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 56.030826 µT | 1501 / 0–30 s |
| Outcome field | 55.906553 µT | 3000 / 240–300 s |
| Absolute change | 124.3 nT | same windows |
| Angular change | 0.184° | same windows |
Summary: CONTROL; -124.3 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15005 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.0005565 µT/s (-0.166982 µT over 0.0–300.1 s, N=15005) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 283–293 s | 10 s | -240.6 nT | 7.05 | 499 |
| 282–292 s | 10 s | -225.8 nT | 6.61 | 501 |
| 284–294 s | 10 s | -225.4 nT | 6.60 | 500 |
| 290–300 s | 10 s | -224.7 nT | 6.58 | 500 |
| 286–296 s | 10 s | -223.9 nT | 6.56 | 500 |
| 289–299 s | 10 s | -218.3 nT | 6.39 | 501 |
| 281–291 s | 10 s | -217.6 nT | 6.37 | 501 |
| 287–297 s | 10 s | -216.8 nT | 6.35 | 501 |
| 285–295 s | 10 s | -216.3 nT | 6.33 | 501 |
| 280–300 s | 20 s | -214.0 nT | 6.27 | 1001 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.