| Practitioner | unknown |
| Condition | CONTROL |
| Analyzer | maglab-analyzer v24 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-28T23:41:55+00:00 |
| App | 38 |
| Duration | 300.329 s |
| Run quality | COMPLETE |
Signed field change: -187.0 nT (-0.332%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 56.340491 µT | 1500 / 0–30 s |
| Outcome field | 56.153493 µT | 3000 / 240–300 s |
| Absolute change | 187.0 nT | same windows |
| Angular change | 0.262° | same windows |
Summary: CONTROL; -187.0 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15004 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.0007645 µT/s (-0.229395 µT over 0.0–300.1 s, N=15004) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 284–294 s | 10 s | -258.6 nT | 9.85 | 499 |
| 282–292 s | 10 s | -252.3 nT | 9.61 | 500 |
| 283–293 s | 10 s | -241.7 nT | 9.21 | 501 |
| 280–290 s | 10 s | -237.6 nT | 9.05 | 499 |
| 281–291 s | 10 s | -229.7 nT | 8.75 | 500 |
| 276–286 s | 10 s | -227.0 nT | 8.65 | 500 |
| 285–295 s | 10 s | -227.0 nT | 8.65 | 500 |
| 277–287 s | 10 s | -226.3 nT | 8.62 | 500 |
| 278–288 s | 10 s | -226.0 nT | 8.61 | 500 |
| 280–300 s | 20 s | -223.9 nT | 8.53 | 999 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.