Run 100791 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v24
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-28T23:41:55+00:00
App 38
Duration 300.329 s
Run quality COMPLETE

Primary result

Signed field change: -187.0 nT (-0.332%)

Measure Value N / window
Reference field 56.340491 µT 1500 / 0–30 s
Outcome field 56.153493 µT 3000 / 240–300 s
Absolute change 187.0 nT same windows
Angular change 0.262° same windows

Summary: CONTROL; -187.0 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15004 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.0007645 µT/s (-0.229395 µT over 0.0–300.1 s, N=15004)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
284–294 s 10 s -258.6 nT 9.85 499
282–292 s 10 s -252.3 nT 9.61 500
283–293 s 10 s -241.7 nT 9.21 501
280–290 s 10 s -237.6 nT 9.05 499
281–291 s 10 s -229.7 nT 8.75 500
276–286 s 10 s -227.0 nT 8.65 500
285–295 s 10 s -227.0 nT 8.65 500
277–287 s 10 s -226.3 nT 8.62 500
278–288 s 10 s -226.0 nT 8.61 500
280–300 s 20 s -223.9 nT 8.53 999

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.