| Practitioner | unknown |
| Condition | CONTROL |
| Analyzer | maglab-analyzer v24 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-28T20:41:39+00:00 |
| App | 38 |
| Duration | 300.352 s |
| Run quality | COMPLETE |
Signed field change: +111.7 nT (+0.200%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 55.841032 µT | 1501 / 0–30 s |
| Outcome field | 55.952711 µT | 3000 / 240–300 s |
| Absolute change | 111.7 nT | same windows |
| Angular change | 0.033° | same windows |
Summary: CONTROL; +111.7 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15002 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts 0.0003445 µT/s (0.103347 µT over 0.0–300.0 s, N=15002) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 203–213 s | 10 s | 200.2 nT | 7.78 | 499 |
| 204–214 s | 10 s | 186.5 nT | 7.24 | 501 |
| 199–209 s | 10 s | 186.0 nT | 7.22 | 499 |
| 205–215 s | 10 s | 182.8 nT | 7.10 | 501 |
| 200–210 s | 10 s | 182.7 nT | 7.10 | 500 |
| 202–212 s | 10 s | 178.8 nT | 6.95 | 500 |
| 154–164 s | 10 s | 171.0 nT | 6.64 | 501 |
| 198–208 s | 10 s | 170.2 nT | 6.61 | 500 |
| 234–244 s | 10 s | 170.1 nT | 6.60 | 501 |
| 194–214 s | 20 s | 170.0 nT | 6.60 | 1001 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.