Run 100772 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v22
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-28T04:31:33+00:00
App 52
Duration 360.417 s
Run quality COMPLETE

Primary result

Signed field change: -883.8 nT (-1.653%)

Measure Value N / window
Reference field 53.464276 µT 3000 / 0–30 s
Outcome field 52.580436 µT 6000 / 240–300 s
Absolute change 883.8 nT same windows
Angular change 1.136° same windows

Continuous ambient comparison

Compared with 18 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +272.4 nT.

Summary: CONTROL; -883.8 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 100 Hz effective over N=36009 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00575495 µT/s (-2.07224 µT over 0.0–360.1 s, N=36009)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
350–360 s 10 s -1819.1 nT 25.73 1000
349–359 s 10 s -1806.2 nT 25.55 1000
348–358 s 10 s -1784.2 nT 25.23 1000
347–357 s 10 s -1733.6 nT 24.52 1000
340–360 s 20 s -1728.8 nT 24.45 2000
346–356 s 10 s -1722.1 nT 24.36 1000
339–359 s 20 s -1709.8 nT 24.18 2000
338–358 s 20 s -1705.3 nT 24.12 2000
345–355 s 10 s -1702.8 nT 24.08 1000
344–354 s 10 s -1698.8 nT 24.03 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.