| Practitioner | unknown |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v22 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-28T03:51:33+00:00 |
| App | 52 |
| Duration | 360.400 s |
| Run quality | COMPLETE |
Signed field change: -1271.1 nT (-2.358%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 53.897699 µT | 2999 / 0–30 s |
| Outcome field | 52.626644 µT | 6000 / 240–300 s |
| Absolute change | 1271.1 nT | same windows |
| Angular change | 1.591° | same windows |
Compared with 15 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +241.6 nT.
Summary: ATTENTION; -1271.1 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 99.9972 Hz effective over N=36009 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.00690483 µT/s (-2.48636 µT over 0.0–360.1 s, N=36009) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | review | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 350–360 s | 10 s | -2514.5 nT | 23.32 | 1001 |
| 349–359 s | 10 s | -2493.4 nT | 23.12 | 1000 |
| 348–358 s | 10 s | -2483.6 nT | 23.03 | 1000 |
| 347–357 s | 10 s | -2475.7 nT | 22.96 | 1000 |
| 346–356 s | 10 s | -2456.1 nT | 22.78 | 1000 |
| 345–355 s | 10 s | -2453.4 nT | 22.75 | 999 |
| 344–354 s | 10 s | -2450.1 nT | 22.72 | 1000 |
| 343–353 s | 10 s | -2447.4 nT | 22.70 | 1000 |
| 340–360 s | 20 s | -2442.7 nT | 22.65 | 2001 |
| 339–359 s | 20 s | -2420.3 nT | 22.45 | 1999 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.