Run 100761 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v22
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-28T02:31:18+00:00
App 52
Duration 385.947 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +1766.8 nT (+3.116%)

Measure Value N / window
Reference field 56.703269 µT 3751 / 0–30 s
Outcome field 58.470113 µT 7500 / 240–300 s
Absolute change 1766.8 nT same windows
Angular change 3.359° same windows

Continuous ambient comparison

Compared with 5 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +1468.0 nT.

Summary: CONTROL; +1766.8 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 125 Hz effective over N=45014 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00783048 µT/s (2.81979 µT over 0.0–360.1 s, N=45014)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
206–216 s 10 s 1890.4 nT 3.44 1251
205–215 s 10 s 1884.1 nT 3.43 1251
207–217 s 10 s 1878.7 nT 3.42 1251
203–213 s 10 s 1876.5 nT 3.41 1250
202–212 s 10 s 1864.1 nT 3.39 1249
204–214 s 10 s 1861.3 nT 3.39 1251
210–220 s 10 s 1861.0 nT 3.39 1251
196–216 s 20 s 1859.1 nT 3.38 2500
197–217 s 20 s 1856.5 nT 3.38 2500
209–219 s 10 s 1855.8 nT 3.38 1251

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.