Run 100736 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v19
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-27T05:25:53+00:00
App 51
Duration 420.431 s
Run quality COMPLETE

Primary result

Signed field change: -874.2 nT (-1.703%)

Measure Value N / window
Reference field 51.329161 µT 1498 / 0–30 s
Outcome field 50.455007 µT 3000 / 240–300 s
Absolute change 874.2 nT same windows
Angular change 1.251° same windows

Continuous ambient comparison

Compared with 7 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +278.3 nT.

Summary: CONTROL; -874.2 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9942 Hz effective over N=20999 samples, 2 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00549486 µT/s (-2.30789 µT over 0.0–420.0 s, N=20999)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
410–420 s 10 s -2255.5 nT 28.27 500
409–419 s 10 s -2247.3 nT 28.16 500
408–418 s 10 s -2210.0 nT 27.70 500
400–420 s 20 s -2187.4 nT 27.41 1000
407–417 s 10 s -2184.1 nT 27.37 500
399–419 s 20 s -2176.4 nT 27.27 1000
406–416 s 10 s -2168.7 nT 27.18 500
405–415 s 10 s -2166.5 nT 27.15 500
398–418 s 20 s -2153.5 nT 26.99 1000
404–414 s 10 s -2144.8 nT 26.88 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.