| Practitioner | Cherylee |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v18 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-26T16:06:50+00:00 |
| App | 49C |
| Duration | 360.501 s |
| Run quality | COMPLETE WITH DATA-QUALITY WARNING |
Signed field change: -91.9 nT (-0.184%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 49.860154 µT | 1496 / 0–30 s |
| Outcome field | 49.768224 µT | 3000 / 240–300 s |
| Absolute change | 91.9 nT | same windows |
| Angular change | 0.331° | same windows |
This run is -67.5 nT relative to Cherylee's 51 historical CONTROL runs (mean -24.4 nT).
Its change is more negative than 84.3% of those controls.
Compared with 10 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +207.4 nT.
Summary: ATTENTION; -91.9 nT; complete with data-quality warning
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 49.987 Hz effective over N=17998 samples, 1 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.0004711 µT/s (-0.1696 µT over 0.0–360.0 s, N=17998) |
| Motion | review | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | review | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 350–360 s | 10 s | -179.2 nT | 5.64 | 500 |
| 347–357 s | 10 s | -176.4 nT | 5.55 | 500 |
| 348–358 s | 10 s | -168.9 nT | 5.32 | 500 |
| 340–360 s | 20 s | -168.5 nT | 5.30 | 1000 |
| 342–352 s | 10 s | -167.5 nT | 5.27 | 500 |
| 349–359 s | 10 s | -166.0 nT | 5.22 | 500 |
| 337–357 s | 20 s | -161.2 nT | 5.07 | 1000 |
| 330–360 s | 30 s | -160.4 nT | 5.05 | 1500 |
| 341–351 s | 10 s | -158.4 nT | 4.99 | 500 |
| 340–350 s | 10 s | -157.7 nT | 4.97 | 500 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.