Run 100699 — CONTROL

Practitioner Cherylee
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-26T15:42:48+00:00
App 49C
Duration 360.508 s
Run quality COMPLETE

Primary result

Signed field change: +30.6 nT (+0.061%)

Measure Value N / window
Reference field 49.888143 µT 1498 / 0–30 s
Outcome field 49.918697 µT 3000 / 240–300 s
Absolute change 30.6 nT same windows
Angular change 0.159° same windows

Cherylee historical comparison

This run is +55.5 nT relative to Cherylee's 49 historical CONTROL runs (mean -24.9 nT).

Its change is more negative than 30.6% of those controls.

Continuous ambient comparison

Compared with 10 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +207.4 nT.

Summary: CONTROL; +30.6 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9923 Hz effective over N=18001 samples, 2 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -8.314e-05 µT/s (-0.0299344 µT over 0.0–360.1 s, N=18001)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
141–151 s 10 s 119.0 nT 4.06 500
140–150 s 10 s 110.5 nT 3.77 500
135–145 s 10 s 102.1 nT 3.48 500
137–147 s 10 s 100.8 nT 3.44 500
134–144 s 10 s 98.2 nT 3.35 500
201–211 s 10 s 97.1 nT 3.31 500
139–149 s 10 s 96.6 nT 3.29 500
200–210 s 10 s 95.5 nT 3.25 500
199–209 s 10 s 93.8 nT 3.20 500
131–151 s 20 s 93.5 nT 3.19 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.