Run 100693 — ATTENTION

Practitioner Cherylee
Condition ATTENTION
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-26T15:19:46+00:00
App 49C
Duration 360.785 s
Run quality COMPLETE

Primary result

Signed field change: -62.2 nT (-0.125%)

Measure Value N / window
Reference field 49.991107 µT 1497 / 0–30 s
Outcome field 49.928860 µT 3000 / 240–300 s
Absolute change 62.2 nT same windows
Angular change 0.283° same windows

Cherylee historical comparison

This run is -37.9 nT relative to Cherylee's 48 historical CONTROL runs (mean -24.3 nT).

Its change is more negative than 72.9% of those controls.

Continuous ambient comparison

Compared with 10 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +207.4 nT.

Summary: ATTENTION; -62.2 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9908 Hz effective over N=17998 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.0004113 µT/s (-0.14806 µT over 0.0–360.0 s, N=17998)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
343–353 s 10 s -235.7 nT 8.82 500
347–357 s 10 s -234.0 nT 8.76 500
344–354 s 10 s -233.0 nT 8.72 500
346–356 s 10 s -222.5 nT 8.32 500
348–358 s 10 s -221.2 nT 8.28 500
342–352 s 10 s -220.5 nT 8.25 500
345–355 s 10 s -219.2 nT 8.20 500
349–359 s 10 s -206.8 nT 7.74 500
341–351 s 10 s -201.3 nT 7.53 500
350–360 s 10 s -193.8 nT 7.25 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.