Run 100673 — CONTROL

Practitioner Alex
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-26T03:02:05+00:00
App 49C
Duration 360.582 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: -1054.1 nT (-2.427%)

Measure Value N / window
Reference field 43.438536 µT 1497 / 0–30 s
Outcome field 42.384437 µT 3000 / 240–300 s
Absolute change 1054.1 nT same windows
Angular change 1.806° same windows

Continuous ambient comparison

Compared with 1 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -3139.6 nT.

Summary: CONTROL; -1054.1 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.989 Hz effective over N=18003 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00484709 µT/s (-1.74553 µT over 0.0–360.1 s, N=18003)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
347–357 s 10 s -1777.8 nT 31.76 500
348–358 s 10 s -1772.2 nT 31.66 500
349–359 s 10 s -1768.9 nT 31.60 500
350–360 s 10 s -1757.3 nT 31.39 500
346–356 s 10 s -1745.1 nT 31.18 500
339–359 s 20 s -1725.9 nT 30.83 1000
340–360 s 20 s -1721.2 nT 30.75 1000
338–358 s 20 s -1721.1 nT 30.75 1000
345–355 s 10 s -1719.8 nT 30.72 500
337–357 s 20 s -1718.1 nT 30.69 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.