| Practitioner | Cherylee |
| Condition | CONTROL |
| Analyzer | maglab-analyzer v18 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-26T02:53:50+00:00 |
| App | 49C |
| Duration | 360.390 s |
| Run quality | COMPLETE |
Signed field change: -12.1 nT (-0.024%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 49.812683 µT | 1500 / 0–30 s |
| Outcome field | 49.800605 µT | 3000 / 240–300 s |
| Absolute change | 12.1 nT | same windows |
| Angular change | 0.196° | same windows |
This run is +14.4 nT relative to Cherylee's 44 historical CONTROL runs (mean -26.5 nT).
Its change is more negative than 43.2% of those controls.
Summary: CONTROL; -12.1 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=17994 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.0001059 µT/s (-0.0381196 µT over 0.0–359.9 s, N=17994) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | review | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 344–354 s | 10 s | -75.1 nT | 3.09 | 500 |
| 121–131 s | 10 s | 74.7 nT | 3.08 | 500 |
| 343–353 s | 10 s | -74.5 nT | 3.07 | 500 |
| 342–352 s | 10 s | -70.6 nT | 2.91 | 500 |
| 324–334 s | 10 s | -68.7 nT | 2.83 | 500 |
| 300–310 s | 10 s | -68.2 nT | 2.81 | 499 |
| 331–341 s | 10 s | -68.0 nT | 2.80 | 500 |
| 327–337 s | 10 s | -67.7 nT | 2.79 | 500 |
| 347–357 s | 10 s | -67.6 nT | 2.78 | 500 |
| 329–339 s | 10 s | -67.1 nT | 2.76 | 500 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.