Run 100603 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-25T02:32:33+00:00
App 48G
Duration 514.674 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +1036.6 nT (+2.585%)

Measure Value N / window
Reference field 40.098709 µT 1500 / 0–30 s
Outcome field 41.135356 µT 3001 / 240–300 s
Absolute change 1036.6 nT same windows
Angular change 0.608° same windows

Continuous ambient comparison

Compared with 4 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +240.6 nT.

Summary: CONTROL; +1036.6 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9972 Hz effective over N=18010 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00370488 µT/s (1.3345 µT over 0.0–360.2 s, N=18010)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
263–273 s 10 s 1187.3 nT 10.66 500
262–272 s 10 s 1176.8 nT 10.57 501
261–271 s 10 s 1172.8 nT 10.53 500
264–274 s 10 s 1171.6 nT 10.52 500
265–275 s 10 s 1164.0 nT 10.45 501
266–276 s 10 s 1150.5 nT 10.33 500
260–270 s 10 s 1148.6 nT 10.31 501
267–277 s 10 s 1141.7 nT 10.25 499
259–269 s 10 s 1140.5 nT 10.24 501
259–279 s 20 s 1117.9 nT 10.04 1001

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.