Run 100584 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-25T02:00:33+00:00
App 48G
Duration 360.327 s
Run quality COMPLETE

Primary result

Signed field change: +47.5 nT (+0.110%)

Measure Value N / window
Reference field 43.127340 µT 1497 / 0–30 s
Outcome field 43.174860 µT 3000 / 240–300 s
Absolute change 47.5 nT same windows
Angular change 0.119° same windows

Continuous ambient comparison

Compared with 12 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -11.8 nT.

Summary: CONTROL; +47.5 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9914 Hz effective over N=18000 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.0003748 µT/s (0.134951 µT over 0.0–360.0 s, N=18000)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
347–357 s 10 s 163.1 nT 9.61 500
348–358 s 10 s 157.9 nT 9.30 500
343–353 s 10 s 155.5 nT 9.16 500
344–354 s 10 s 154.1 nT 9.07 500
346–356 s 10 s 153.9 nT 9.06 500
349–359 s 10 s 151.6 nT 8.93 500
350–360 s 10 s 151.4 nT 8.92 500
345–355 s 10 s 151.3 nT 8.91 500
342–352 s 10 s 141.3 nT 8.32 500
340–360 s 20 s 137.0 nT 8.06 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.