| Practitioner | unknown |
| Condition | CONTROL |
| Analyzer | maglab-analyzer v18 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-25T00:24:14+00:00 |
| App | 48G |
| Duration | 62.627 s |
| Run quality | INCOMPLETE |
Primary result unavailable: primary windows lack 80% sample coverage
Summary: CONTROL; primary result unavailable; incomplete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 49.9971 Hz effective over N=3116 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts 0.00283068 µT/s (0.176361 µT over 0.0–62.3 s, N=3116) |
| Motion | review | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 48–58 s | 10 s | -310.7 nT | 3.88 | 500 |
| 47–57 s | 10 s | -310.6 nT | 3.88 | 500 |
| 46–56 s | 10 s | -291.9 nT | 3.64 | 500 |
| 45–55 s | 10 s | -277.6 nT | 3.46 | 500 |
| 44–54 s | 10 s | -262.5 nT | 3.28 | 500 |
| 43–53 s | 10 s | -251.0 nT | 3.13 | 500 |
| 42–52 s | 10 s | -231.4 nT | 2.89 | 500 |
| 38–58 s | 20 s | -201.1 nT | 2.51 | 1000 |
| 41–51 s | 10 s | -190.1 nT | 2.37 | 500 |
| 37–57 s | 20 s | -185.9 nT | 2.32 | 1000 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.