Run 100563 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-24T23:39:08+00:00
App 48G
Duration 360.332 s
Run quality COMPLETE

Primary result

Signed field change: +0.7 nT (+0.001%)

Measure Value N / window
Reference field 47.745793 µT 1497 / 0–30 s
Outcome field 47.746446 µT 3000 / 240–300 s
Absolute change 0.7 nT same windows
Angular change 0.052° same windows

Continuous ambient comparison

Compared with 10 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +2.9 nT.

Summary: CONTROL; +0.7 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9905 Hz effective over N=18001 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 3.768e-05 µT/s (0.0135673 µT over 0.0–360.1 s, N=18001)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
134–144 s 10 s -62.5 nT 3.28 500
334–344 s 10 s 61.2 nT 3.21 500
133–143 s 10 s -59.5 nT 3.12 500
132–142 s 10 s -59.5 nT 3.12 500
335–345 s 10 s 58.3 nT 3.05 500
283–293 s 10 s -54.8 nT 2.87 500
162–172 s 10 s -50.8 nT 2.66 500
131–141 s 10 s -50.0 nT 2.62 500
333–343 s 10 s 49.9 nT 2.62 500
338–348 s 10 s 49.7 nT 2.60 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.