Run 100548 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-24T23:24:08+00:00
App 48G
Duration 360.636 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +81.2 nT (+0.100%)

Measure Value N / window
Reference field 81.504824 µT 1496 / 0–30 s
Outcome field 81.586025 µT 3000 / 240–300 s
Absolute change 81.2 nT same windows
Angular change 0.028° same windows

Continuous ambient comparison

Compared with 10 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +2.9 nT.

Summary: CONTROL; +81.2 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9889 Hz effective over N=18008 samples, 2 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.0004987 µT/s (0.179643 µT over 0.0–360.2 s, N=18008)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.