Run 100540 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-24T21:57:00+00:00
App 48G
Duration 510.902 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +1282.0 nT (+3.222%)

Measure Value N / window
Reference field 39.785311 µT 1499 / 0–30 s
Outcome field 41.067275 µT 3000 / 240–300 s
Absolute change 1282.0 nT same windows
Angular change 0.150° same windows

Continuous ambient comparison

Compared with 206 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +313.6 nT.

Summary: CONTROL; +1282.0 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9972 Hz effective over N=18006 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00429826 µT/s (1.54789 µT over 0.0–360.1 s, N=18006)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
326–336 s 10 s 1419.3 nT 14.43 501
325–335 s 10 s 1413.8 nT 14.38 499
324–334 s 10 s 1411.6 nT 14.35 501
327–337 s 10 s 1411.5 nT 14.35 500
328–338 s 10 s 1396.0 nT 14.19 499
323–333 s 10 s 1395.6 nT 14.19 501
322–332 s 10 s 1393.0 nT 14.16 501
321–331 s 10 s 1387.1 nT 14.10 500
329–339 s 10 s 1384.3 nT 14.08 499
321–341 s 20 s 1381.2 nT 14.04 999

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.