| Practitioner | Alex |
| Condition | CONTROL |
| Analyzer | maglab-analyzer v18 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-24T21:41:59+00:00 |
| App | 48G |
| Duration | 360.251 s |
| Run quality | COMPLETE |
Signed field change: -113.0 nT (-0.166%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 68.221743 µT | 1500 / 0–30 s |
| Outcome field | 68.108699 µT | 3001 / 240–300 s |
| Absolute change | 113.0 nT | same windows |
| Angular change | 0.257° | same windows |
Compared with 3 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -11925.6 nT.
Summary: CONTROL; -113.0 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=18004 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.00107473 µT/s (-0.386966 µT over 0.0–360.1 s, N=18004) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | review | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 350–360 s | 10 s | -402.9 nT | 10.66 | 501 |
| 349–359 s | 10 s | -384.3 nT | 10.17 | 499 |
| 347–357 s | 10 s | -381.3 nT | 10.09 | 500 |
| 345–355 s | 10 s | -379.0 nT | 10.03 | 499 |
| 344–354 s | 10 s | -374.0 nT | 9.89 | 501 |
| 348–358 s | 10 s | -370.4 nT | 9.80 | 500 |
| 346–356 s | 10 s | -369.7 nT | 9.78 | 501 |
| 340–360 s | 20 s | -366.8 nT | 9.70 | 1000 |
| 343–353 s | 10 s | -361.3 nT | 9.56 | 500 |
| 342–352 s | 10 s | -352.5 nT | 9.33 | 501 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.