| Practitioner | Cherylee |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v18 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-24T06:11:48+00:00 |
| App | 48G |
| Duration | 360.818 s |
| Run quality | COMPLETE |
Signed field change: -222.3 nT (-0.440%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 50.526273 µT | 1499 / 0–30 s |
| Outcome field | 50.303926 µT | 3000 / 240–300 s |
| Absolute change | 222.3 nT | same windows |
| Angular change | 0.392° | same windows |
This run is -197.6 nT relative to Cherylee's 40 historical CONTROL runs (mean -24.7 nT).
Its change is more negative than 97.5% of those controls.
Summary: ATTENTION; -222.3 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 49.9959 Hz effective over N=17995 samples, 2 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.00132801 µT/s (-0.477964 µT over 0.0–359.9 s, N=17995) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | review | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 329–339 s | 10 s | -519.6 nT | 14.92 | 500 |
| 331–341 s | 10 s | -512.6 nT | 14.71 | 500 |
| 330–340 s | 10 s | -507.7 nT | 14.57 | 500 |
| 347–357 s | 10 s | -504.0 nT | 14.47 | 500 |
| 328–338 s | 10 s | -498.7 nT | 14.32 | 500 |
| 348–358 s | 10 s | -498.5 nT | 14.31 | 500 |
| 349–359 s | 10 s | -497.4 nT | 14.28 | 500 |
| 345–355 s | 10 s | -495.6 nT | 14.23 | 500 |
| 329–359 s | 30 s | -490.4 nT | 14.08 | 1500 |
| 332–342 s | 10 s | -489.5 nT | 14.05 | 500 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.