Run 100508 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-24T05:17:41+00:00
App 48G
Duration 360.540 s
Run quality COMPLETE

Primary result

Signed field change: -1093.0 nT (-2.139%)

Measure Value N / window
Reference field 51.098341 µT 1497 / 0–30 s
Outcome field 50.005376 µT 3000 / 240–300 s
Absolute change 1093.0 nT same windows
Angular change 1.024° same windows

Continuous ambient comparison

Compared with 3 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +590.0 nT.

Summary: CONTROL; -1093.0 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9913 Hz effective over N=17995 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00494054 µT/s (-1.77831 µT over 0.0–359.9 s, N=17995)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
349–359 s 10 s -1753.7 nT 23.29 500
348–358 s 10 s -1734.1 nT 23.03 500
344–354 s 10 s -1730.1 nT 22.97 500
343–353 s 10 s -1726.0 nT 22.92 500
345–355 s 10 s -1722.8 nT 22.88 500
346–356 s 10 s -1721.6 nT 22.86 500
347–357 s 10 s -1716.0 nT 22.79 500
339–359 s 20 s -1709.6 nT 22.70 1000
341–351 s 10 s -1701.3 nT 22.59 500
340–350 s 10 s -1696.3 nT 22.53 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.