| Practitioner | unknown |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v18 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-24T04:49:37+00:00 |
| App | 48G |
| Duration | 360.408 s |
| Run quality | COMPLETE |
Signed field change: -852.5 nT (-1.612%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 52.871919 µT | 1500 / 0–30 s |
| Outcome field | 52.019370 µT | 3000 / 240–300 s |
| Absolute change | 852.5 nT | same windows |
| Angular change | 1.428° | same windows |
Summary: ATTENTION; -852.5 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=17998 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.00438762 µT/s (-1.57928 µT over 0.0–359.9 s, N=17998) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | review | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 349–359 s | 10 s | -1448.8 nT | 21.47 | 500 |
| 348–358 s | 10 s | -1446.9 nT | 21.44 | 500 |
| 339–359 s | 20 s | -1420.9 nT | 21.06 | 1000 |
| 338–358 s | 20 s | -1412.4 nT | 20.93 | 1000 |
| 341–351 s | 10 s | -1405.5 nT | 20.83 | 500 |
| 340–350 s | 10 s | -1404.0 nT | 20.81 | 500 |
| 346–356 s | 10 s | -1403.3 nT | 20.80 | 500 |
| 347–357 s | 10 s | -1401.9 nT | 20.78 | 500 |
| 336–356 s | 20 s | -1401.7 nT | 20.77 | 1000 |
| 336–346 s | 10 s | -1400.1 nT | 20.75 | 500 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.