Run 100503 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-24T04:43:36+00:00
App 48G
Duration 360.540 s
Run quality COMPLETE

Primary result

Signed field change: -790.7 nT (-1.495%)

Measure Value N / window
Reference field 52.899987 µT 1499 / 0–30 s
Outcome field 52.109305 µT 3000 / 240–300 s
Absolute change 790.7 nT same windows
Angular change 1.053° same windows

Summary: CONTROL; -790.7 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9946 Hz effective over N=17997 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00404406 µT/s (-1.4557 µT over 0.0–360.0 s, N=17997)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
349–359 s 10 s -1410.3 nT 22.32 500
347–357 s 10 s -1404.5 nT 22.23 500
346–356 s 10 s -1403.0 nT 22.21 500
348–358 s 10 s -1396.6 nT 22.10 500
345–355 s 10 s -1375.5 nT 21.77 500
339–359 s 20 s -1374.3 nT 21.75 1000
338–358 s 20 s -1358.6 nT 21.50 1000
344–354 s 10 s -1358.2 nT 21.50 500
342–352 s 10 s -1355.2 nT 21.45 500
337–357 s 20 s -1352.3 nT 21.40 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.