Run 100499 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-24T04:30:38+00:00
App 48G
Duration 360.546 s
Run quality COMPLETE

Primary result

Signed field change: -909.3 nT (-1.715%)

Measure Value N / window
Reference field 53.033957 µT 1500 / 0–30 s
Outcome field 52.124631 µT 3000 / 240–300 s
Absolute change 909.3 nT same windows
Angular change 1.181° same windows

Summary: CONTROL; -909.3 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9995 Hz effective over N=18005 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.00421514 µT/s (-1.5178 µT over 0.0–360.1 s, N=18005)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
348–358 s 10 s -1468.2 nT 23.31 500
350–360 s 10 s -1464.3 nT 23.25 500
349–359 s 10 s -1458.4 nT 23.15 500
347–357 s 10 s -1431.7 nT 22.73 500
340–360 s 20 s -1428.4 nT 22.68 1000
339–359 s 20 s -1415.0 nT 22.47 1000
346–356 s 10 s -1412.3 nT 22.42 500
338–358 s 20 s -1408.2 nT 22.36 1000
337–357 s 20 s -1397.2 nT 22.18 1000
344–354 s 10 s -1395.7 nT 22.16 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.