Run 100457 — ATTENTION

Practitioner Cherylee
Condition ATTENTION
Analyzer maglab-analyzer v18
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-23T03:14:34+00:00
App 45
Duration 300.277 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: -61.1 nT (-0.117%)

Measure Value N / window
Reference field 52.114880 µT 1501 / 0–30 s
Outcome field 52.053801 µT 3000 / 240–300 s
Absolute change 61.1 nT same windows
Angular change 0.531° same windows

Cherylee historical comparison

This run is -34.6 nT relative to Cherylee's 36 historical CONTROL runs (mean -26.5 nT).

Its change is more negative than 69.4% of those controls.

Continuous ambient comparison

Compared with 24 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +79.3 nT.

Summary: ATTENTION; -61.1 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15004 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.0001728 µT/s (-0.0518574 µT over 0.0–300.1 s, N=15004)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
267–277 s 10 s -102.6 nT 2.79 500
268–278 s 10 s -102.2 nT 2.78 500
266–276 s 10 s -101.6 nT 2.77 500
273–283 s 10 s -99.4 nT 2.71 500
262–272 s 10 s -97.7 nT 2.66 500
269–279 s 10 s -97.3 nT 2.65 500
263–283 s 20 s -96.6 nT 2.63 1000
265–275 s 10 s -94.6 nT 2.58 500
263–273 s 10 s -93.8 nT 2.55 500
262–282 s 20 s -93.4 nT 2.54 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.