| Practitioner | Cherylee |
| Condition | CONTROL |
| Analyzer | maglab-analyzer v18 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-23T02:56:29+00:00 |
| App | 45 |
| Duration | 300.258 s |
| Run quality | COMPLETE |
Signed field change: +351.9 nT (+0.686%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 51.290450 µT | 1500 / 0–30 s |
| Outcome field | 51.642346 µT | 3000 / 240–300 s |
| Absolute change | 351.9 nT | same windows |
| Angular change | 0.685° | same windows |
This run is +389.3 nT relative to Cherylee's 35 historical CONTROL runs (mean -37.4 nT).
Its change is more negative than 0.0% of those controls.
Compared with 24 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +79.3 nT.
Summary: CONTROL; +351.9 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15002 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts 0.00149467 µT/s (0.448429 µT over 0.0–300.0 s, N=15002) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 237–247 s | 10 s | 404.0 nT | 10.72 | 501 |
| 237–257 s | 20 s | 391.5 nT | 10.39 | 1000 |
| 232–242 s | 10 s | 389.7 nT | 10.35 | 500 |
| 246–256 s | 10 s | 388.4 nT | 10.31 | 500 |
| 236–256 s | 20 s | 388.2 nT | 10.31 | 1000 |
| 236–246 s | 10 s | 388.1 nT | 10.30 | 500 |
| 238–248 s | 10 s | 385.2 nT | 10.23 | 500 |
| 269–279 s | 10 s | 383.7 nT | 10.19 | 500 |
| 234–244 s | 10 s | 383.4 nT | 10.18 | 500 |
| 235–245 s | 10 s | 383.0 nT | 10.17 | 501 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.