Run 100439 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v17
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-22T16:27:12+00:00
App 39
Duration 306.349 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: -19224.8 nT (-27.242%)

Measure Value N / window
Reference field 70.569665 µT 1501 / 0–30 s
Outcome field 51.344885 µT 3000 / 240–300 s
Absolute change 19224.8 nT same windows
Angular change 29.437° same windows

Continuous ambient comparison

Compared with 160 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -510.1 nT.

Summary: CONTROL; -19224.8 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15003 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.0832498 µT/s (-24.9783 µT over 0.0–300.0 s, N=15003)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
123–133 s 10 s -20034.2 nT 1.96 500
122–132 s 10 s -20030.2 nT 1.96 501
124–134 s 10 s -20027.0 nT 1.96 500
125–135 s 10 s -20011.8 nT 1.96 500
126–136 s 10 s -20006.6 nT 1.96 500
121–131 s 10 s -20004.5 nT 1.96 500
127–137 s 10 s -20003.2 nT 1.96 500
128–138 s 10 s -19996.1 nT 1.96 500
116–136 s 20 s -19985.9 nT 1.96 1000
129–139 s 10 s -19985.8 nT 1.96 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.