Run 100430 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v16
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-22T05:06:06+00:00
App 38
Duration 300.270 s
Run quality COMPLETE

Primary result

Signed field change: -1162.4 nT (-1.854%)

Measure Value N / window
Reference field 62.713984 µT 1500 / 0–30 s
Outcome field 61.551540 µT 3000 / 240–300 s
Absolute change 1162.4 nT same windows
Angular change 0.316° same windows

Continuous ambient comparison

Compared with 40 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +63.6 nT.

Summary: CONTROL; -1162.4 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15002 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.004523 µT/s (-1.35699 µT over 0.0–300.0 s, N=15002)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
275–285 s 10 s -1466.5 nT 15.84 500
274–284 s 10 s -1443.1 nT 15.59 500
276–286 s 10 s -1425.2 nT 15.40 500
273–283 s 10 s -1414.5 nT 15.28 500
272–282 s 10 s -1410.3 nT 15.24 500
277–287 s 10 s -1406.5 nT 15.20 500
271–281 s 10 s -1383.8 nT 14.95 500
278–288 s 10 s -1367.3 nT 14.77 500
270–280 s 10 s -1366.2 nT 14.76 500
266–286 s 20 s -1357.1 nT 14.66 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.