| Practitioner | Cherylee |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v16 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-22T02:31:15+00:00 |
| App | 38 |
| Duration | 300.393 s |
| Run quality | COMPLETE |
Signed field change: -98.5 nT (-0.167%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 59.070162 µT | 1501 / 0–30 s |
| Outcome field | 58.971638 µT | 3001 / 240–300 s |
| Absolute change | 98.5 nT | same windows |
| Angular change | 0.436° | same windows |
This run is -59.8 nT relative to Cherylee's 31 historical CONTROL runs (mean -38.7 nT).
Its change is more negative than 83.9% of those controls.
Summary: ATTENTION; -98.5 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15005 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.0003667 µT/s (-0.110051 µT over 0.0–300.1 s, N=15005) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 261–271 s | 10 s | -140.3 nT | 4.40 | 500 |
| 262–272 s | 10 s | -135.2 nT | 4.24 | 501 |
| 263–273 s | 10 s | -132.2 nT | 4.14 | 500 |
| 266–276 s | 10 s | -125.4 nT | 3.93 | 500 |
| 264–274 s | 10 s | -124.7 nT | 3.91 | 500 |
| 257–267 s | 10 s | -123.2 nT | 3.86 | 500 |
| 257–277 s | 20 s | -122.0 nT | 3.82 | 1000 |
| 267–277 s | 10 s | -120.8 nT | 3.79 | 500 |
| 256–276 s | 20 s | -120.7 nT | 3.78 | 1000 |
| 260–270 s | 10 s | -118.9 nT | 3.72 | 500 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.