Run 100411 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v16
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-22T02:10:32+00:00
App 38
Duration 300.237 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: -3.7 nT (-0.007%)

Measure Value N / window
Reference field 49.143813 µT 1500 / 0–30 s
Outcome field 49.140151 µT 3000 / 240–300 s
Absolute change 3.7 nT same windows
Angular change 1.303° same windows

Continuous ambient comparison

Compared with 20 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +763.9 nT.

Summary: CONTROL; -3.7 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15002 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.0007876 µT/s (-0.236303 µT over 0.0–300.0 s, N=15002)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
56–66 s 10 s 346.8 nT 3.89 500
58–68 s 10 s 345.3 nT 3.88 500
33–43 s 10 s 345.1 nT 3.87 500
44–54 s 10 s 344.9 nT 3.87 501
31–41 s 10 s 343.7 nT 3.86 499
46–66 s 20 s 343.2 nT 3.85 1000
57–67 s 10 s 342.9 nT 3.85 500
60–70 s 10 s 342.8 nT 3.85 500
48–68 s 20 s 342.8 nT 3.85 1000
32–42 s 10 s 342.8 nT 3.85 499

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.