Run 100398 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v16
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-21T21:42:43+00:00
App 38
Duration 300.222 s
Run quality COMPLETE

Primary result

Signed field change: +223.1 nT (+0.554%)

Measure Value N / window
Reference field 40.285145 µT 1500 / 0–30 s
Outcome field 40.508232 µT 3000 / 240–300 s
Absolute change 223.1 nT same windows
Angular change 1.455° same windows

Continuous ambient comparison

Compared with 86 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -1046.2 nT.

Summary: CONTROL; +223.1 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9999 Hz effective over N=15004 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00068 µT/s (0.20403 µT over 0.0–300.1 s, N=15004)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
221–231 s 10 s 250.6 nT 4.64 500
230–240 s 10 s 249.0 nT 4.61 500
222–232 s 10 s 247.4 nT 4.58 500
221–241 s 20 s 246.5 nT 4.57 1000
224–234 s 10 s 246.5 nT 4.57 500
225–235 s 10 s 245.9 nT 4.56 500
223–233 s 10 s 245.0 nT 4.54 500
226–236 s 10 s 244.9 nT 4.54 500
229–239 s 10 s 244.2 nT 4.52 500
228–238 s 10 s 243.9 nT 4.52 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.