| Practitioner | unknown |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v16 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-21T21:03:31+00:00 |
| App | 38 |
| Duration | 300.220 s |
| Run quality | COMPLETE |
Signed field change: -743.1 nT (-1.348%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 55.132688 µT | 1500 / 0–30 s |
| Outcome field | 54.389543 µT | 3000 / 240–300 s |
| Absolute change | 743.1 nT | same windows |
| Angular change | 0.759° | same windows |
Compared with 20 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -1727.0 nT.
Summary: ATTENTION; -743.1 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15004 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.00304425 µT/s (-0.913458 µT over 0.0–300.1 s, N=15004) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 290–300 s | 10 s | -952.8 nT | 16.48 | 500 |
| 286–296 s | 10 s | -945.4 nT | 16.35 | 500 |
| 285–295 s | 10 s | -942.3 nT | 16.30 | 500 |
| 288–298 s | 10 s | -940.0 nT | 16.26 | 500 |
| 289–299 s | 10 s | -936.7 nT | 16.20 | 500 |
| 287–297 s | 10 s | -928.6 nT | 16.06 | 500 |
| 284–294 s | 10 s | -911.1 nT | 15.76 | 500 |
| 280–300 s | 20 s | -903.0 nT | 15.62 | 1000 |
| 283–293 s | 10 s | -902.9 nT | 15.62 | 500 |
| 279–299 s | 20 s | -900.3 nT | 15.57 | 1000 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.