Signed field change: -849.4 nT (-1.671%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 50.844419 µT | 1500 / 0–30 s |
| Outcome field | 49.995052 µT | 3000 / 240–300 s |
| Absolute change | 849.4 nT | same windows |
| Angular change | 1.299° | same windows |
Compared with 7 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +88.3 nT.
Summary: ATTENTION; -849.4 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15001 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.0034346 µT/s (-1.03038 µT over 0.0–300.0 s, N=15001) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 268–278 s | 10 s | -1357.3 nT | 10.72 | 500 |
| 269–279 s | 10 s | -1346.0 nT | 10.63 | 500 |
| 267–277 s | 10 s | -1326.3 nT | 10.47 | 500 |
| 264–274 s | 10 s | -1301.6 nT | 10.28 | 500 |
| 266–276 s | 10 s | -1297.1 nT | 10.24 | 500 |
| 263–273 s | 10 s | -1292.4 nT | 10.20 | 500 |
| 265–275 s | 10 s | -1284.1 nT | 10.14 | 500 |
| 270–280 s | 10 s | -1204.1 nT | 9.51 | 500 |
| 262–272 s | 10 s | -1191.4 nT | 9.41 | 500 |
| 269–289 s | 20 s | -1126.6 nT | 8.90 | 1000 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.