Run 100381 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v16
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-21T14:06:19+00:00
App 38
Duration 300.245 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +598.8 nT (+1.397%)

Measure Value N / window
Reference field 42.875435 µT 1501 / 0–30 s
Outcome field 43.474204 µT 3000 / 240–300 s
Absolute change 598.8 nT same windows
Angular change 0.073° same windows

Continuous ambient comparison

Compared with 1 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -501.8 nT.

Summary: CONTROL; +598.8 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15009 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00250361 µT/s (0.751483 µT over 0.0–300.2 s, N=15009)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
283–293 s 10 s 713.5 nT 18.71 500
284–294 s 10 s 712.4 nT 18.68 501
280–290 s 10 s 712.0 nT 18.67 500
278–288 s 10 s 711.9 nT 18.66 499
282–292 s 10 s 711.5 nT 18.65 500
285–295 s 10 s 710.8 nT 18.63 499
279–289 s 10 s 709.0 nT 18.59 501
286–296 s 10 s 708.1 nT 18.56 501
281–291 s 10 s 707.7 nT 18.55 499
280–300 s 20 s 705.7 nT 18.50 1000

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.