Run 100380 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v16
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-21T14:04:17+00:00
App 38
Duration 300.213 s
Run quality COMPLETE

Primary result

Signed field change: +247.9 nT (+0.484%)

Measure Value N / window
Reference field 51.188623 µT 1500 / 0–30 s
Outcome field 51.436496 µT 3000 / 240–300 s
Absolute change 247.9 nT same windows
Angular change 0.453° same windows

Continuous ambient comparison

Compared with 2 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -45814.3 nT.

Summary: CONTROL; +247.9 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9999 Hz effective over N=15004 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.0009257 µT/s (0.277765 µT over 0.0–300.1 s, N=15004)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
62–72 s 10 s 380.5 nT 3.48 500
61–71 s 10 s 368.3 nT 3.37 500
288–298 s 10 s 359.5 nT 3.29 500
289–299 s 10 s 352.0 nT 3.22 500
60–70 s 10 s 351.5 nT 3.21 500
287–297 s 10 s 350.5 nT 3.20 500
63–73 s 10 s 346.5 nT 3.17 500
59–69 s 10 s 340.1 nT 3.11 500
286–296 s 10 s 329.3 nT 3.01 500
290–300 s 10 s 326.5 nT 2.99 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.