Run 100378 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v16
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-21T14:01:18+00:00
App 38
Duration 300.376 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +774.9 nT (+1.814%)

Measure Value N / window
Reference field 42.711244 µT 1500 / 0–30 s
Outcome field 43.486121 µT 2999 / 240–300 s
Absolute change 774.9 nT same windows
Angular change 0.931° same windows

Summary: CONTROL; +774.9 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15014 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00325663 µT/s (0.977835 µT over 0.0–300.3 s, N=15014)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
236–246 s 10 s 986.4 nT 6.65 500
235–245 s 10 s 985.9 nT 6.64 500
234–244 s 10 s 966.0 nT 6.51 500
233–243 s 10 s 962.3 nT 6.48 500
237–247 s 10 s 938.7 nT 6.33 499
232–242 s 10 s 918.5 nT 6.19 500
238–248 s 10 s 852.0 nT 5.74 500
290–300 s 10 s 849.6 nT 5.72 499
286–296 s 10 s 845.8 nT 5.70 500
285–295 s 10 s 845.5 nT 5.70 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.