| Practitioner | Alex |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v15 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-21T01:39:54+00:00 |
| App | 38 |
| Duration | 974.940 s |
| Run quality | COMPLETE |
Signed field change: -435.9 nT (-1.006%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 43.308734 µT | 1501 / 0–30 s |
| Outcome field | 42.872845 µT | 3000 / 240–300 s |
| Absolute change | 435.9 nT | same windows |
| Angular change | 0.827° | same windows |
Compared with 13 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -292.7 nT.
Summary: ATTENTION; -435.9 nT; complete
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 48.5511 Hz effective over N=38837 samples, 406 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.00732461 µT/s (-5.85896 µT over 0.0–799.9 s, N=38837) |
| Motion | pass | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | review | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 754–764 s | 10 s | -4393.2 nT | 40.55 | 500 |
| 752–762 s | 10 s | -4391.4 nT | 40.53 | 500 |
| 755–765 s | 10 s | -4390.9 nT | 40.53 | 500 |
| 751–761 s | 10 s | -4389.2 nT | 40.51 | 500 |
| 753–763 s | 10 s | -4388.6 nT | 40.51 | 500 |
| 747–757 s | 10 s | -4377.7 nT | 40.41 | 500 |
| 749–759 s | 10 s | -4377.6 nT | 40.41 | 500 |
| 748–758 s | 10 s | -4375.0 nT | 40.38 | 500 |
| 750–760 s | 10 s | -4372.1 nT | 40.36 | 500 |
| 745–765 s | 20 s | -4371.2 nT | 40.35 | 1000 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.