| Practitioner | Cherylee |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v12 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-19T02:56:24+00:00 |
| App | 35 |
| Duration | 300.486 s |
| Run quality | COMPLETE WITH DATA-QUALITY WARNING |
Signed field change: -96.4 nT (-0.217%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 44.409863 µT | 1501 / 0–30 s |
| Outcome field | 44.313415 µT | 3000 / 240–300 s |
| Absolute change | 96.4 nT | same windows |
| Angular change | 0.901° | same windows |
This run is -87.5 nT relative to Cherylee's 22 historical CONTROL runs (mean -8.9 nT).
Its change is more negative than 81.8% of those controls.
Compared with 7 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +1032.6 nT.
Summary: ATTENTION; -96.4 nT; complete with data-quality warning
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15002 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts -0.000385 µT/s (-0.115499 µT over 0.0–300.0 s, N=15002) |
| Motion | review | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 268–278 s | 10 s | -131.8 nT | 6.45 | 500 |
| 269–279 s | 10 s | -131.6 nT | 6.44 | 500 |
| 267–277 s | 10 s | -127.5 nT | 6.24 | 500 |
| 266–276 s | 10 s | -127.4 nT | 6.23 | 500 |
| 216–226 s | 10 s | -122.3 nT | 5.99 | 500 |
| 271–281 s | 10 s | -118.4 nT | 5.79 | 500 |
| 270–280 s | 10 s | -116.5 nT | 5.70 | 500 |
| 272–282 s | 10 s | -115.9 nT | 5.67 | 500 |
| 259–279 s | 20 s | -115.9 nT | 5.67 | 1000 |
| 253–263 s | 10 s | -112.0 nT | 5.48 | 500 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.