Run 100285 — ATTENTION

Practitioner unknown
Condition ATTENTION
Analyzer maglab-analyzer v10
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-18T12:14:53+00:00
App 31
Duration 300.261 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +329.4 nT (+0.697%)

Measure Value N / window
Reference field 47.269679 µT 1501 / 0–30 s
Outcome field 47.599111 µT 3000 / 240–300 s
Absolute change 329.4 nT same windows
Angular change 0.203° same windows

Continuous ambient comparison

Compared with 104 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -1240.2 nT.

Summary: ATTENTION; +329.4 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15004 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00117462 µT/s (0.352458 µT over 0.0–300.1 s, N=15004)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
273–283 s 10 s 403.3 nT 9.09 500
275–285 s 10 s 396.6 nT 8.94 501
274–284 s 10 s 393.3 nT 8.87 500
271–281 s 10 s 387.0 nT 8.72 500
272–282 s 10 s 386.0 nT 8.70 500
277–287 s 10 s 377.9 nT 8.52 501
270–280 s 10 s 377.3 nT 8.51 500
276–286 s 10 s 377.0 nT 8.50 501
273–293 s 20 s 376.5 nT 8.49 1001
275–295 s 20 s 373.3 nT 8.41 1001

Files

Interpretation boundary