| Practitioner | unknown |
| Condition | ATTENTION |
| Analyzer | maglab-analyzer v10 |
| Report schema | maglab-standard-report-v3 |
| Analysis model | maglab-analysis-v1 |
| Generated UTC | 2026-08-18T11:53:42+00:00 |
| App | 31 |
| Duration | 300.260 s |
| Run quality | COMPLETE WITH DATA-QUALITY WARNING |
Signed field change: +297.1 nT (+0.632%)
| Measure | Value | N / window |
|---|---|---|
| Reference field | 46.997422 µT | 1501 / 0–30 s |
| Outcome field | 47.294495 µT | 3000 / 240–300 s |
| Absolute change | 297.1 nT | same windows |
| Angular change | 0.388° | same windows |
Compared with 100 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -1289.7 nT.
Summary: ATTENTION; +297.1 nT; complete with data-quality warning
| Check | Status | Detail |
|---|---|---|
| Readiness | pass | see metrics.json |
| Sampling | measured | calibrated magnetometer 50 Hz effective over N=15006 samples, 0 gaps |
| Warmup | reported_unrecorded | Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample. |
| Baseline Drift | measured | calibrated |B| drifts 0.00140889 µT/s (0.422807 µT over 0.0–300.1 s, N=15006) |
| Motion | review | Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds. |
| Thermal | pass | see metrics.json |
| Ambient | available | Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome. |
| Rolling Anomaly | measured | Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive. |
| Start–end | Length | Signed change | Score | N |
|---|---|---|---|---|
| 198–208 s | 10 s | 413.8 nT | 5.52 | 500 |
| 197–207 s | 10 s | 396.1 nT | 5.29 | 500 |
| 290–300 s | 10 s | 395.3 nT | 5.27 | 500 |
| 289–299 s | 10 s | 390.5 nT | 5.21 | 500 |
| 196–206 s | 10 s | 385.8 nT | 5.15 | 500 |
| 195–205 s | 10 s | 382.8 nT | 5.11 | 500 |
| 262–272 s | 10 s | 381.5 nT | 5.09 | 500 |
| 261–271 s | 10 s | 371.8 nT | 4.96 | 500 |
| 135–145 s | 10 s | 362.7 nT | 4.84 | 500 |
| 141–151 s | 10 s | 361.9 nT | 4.83 | 500 |
The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.