Run 100273 — ATTENTION

Practitioner unknown
Condition ATTENTION
Analyzer maglab-analyzer v10
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-18T11:40:37+00:00
App 31
Duration 300.297 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +361.2 nT (+0.775%)

Measure Value N / window
Reference field 46.591361 µT 1501 / 0–30 s
Outcome field 46.952516 µT 3000 / 240–300 s
Absolute change 361.2 nT same windows
Angular change 0.080° same windows

Continuous ambient comparison

Compared with 97 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -1332.5 nT.

Summary: ATTENTION; +361.2 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15005 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00142155 µT/s (0.426579 µT over 0.0–300.1 s, N=15005)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
274–284 s 10 s 441.7 nT 8.71 500
270–280 s 10 s 434.6 nT 8.57 500
273–283 s 10 s 427.1 nT 8.42 500
271–281 s 10 s 426.9 nT 8.42 500
272–282 s 10 s 426.1 nT 8.40 500
269–279 s 10 s 419.6 nT 8.27 500
264–284 s 20 s 413.4 nT 8.15 1000
263–283 s 20 s 407.1 nT 8.03 1000
260–280 s 20 s 405.6 nT 8.00 1000
262–282 s 20 s 404.4 nT 7.97 1000

Files

Interpretation boundary