Run 100269 — ATTENTION

Practitioner Cherylee
Condition ATTENTION
Analyzer maglab-analyzer v10
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-18T03:56:04+00:00
App 30
Duration 300.523 s
Run quality COMPLETE

Primary result

Signed field change: -75.4 nT (-0.116%)

Measure Value N / window
Reference field 65.107377 µT 1501 / 0–30 s
Outcome field 65.031945 µT 3000 / 240–300 s
Absolute change 75.4 nT same windows
Angular change 0.402° same windows

Cherylee historical comparison

This run is -58.3 nT relative to Cherylee's 18 historical CONTROL runs (mean -17.1 nT).

Its change is more negative than 72.2% of those controls.

Continuous ambient comparison

Compared with 5 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +30.7 nT.

Summary: ATTENTION; -75.4 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15005 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.0003787 µT/s (-0.113649 µT over 0.0–300.1 s, N=15005)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
268–278 s 10 s -118.2 nT 5.26 501
267–277 s 10 s -116.0 nT 5.16 500
274–284 s 10 s -114.6 nT 5.10 500
266–276 s 10 s -114.2 nT 5.08 500
269–279 s 10 s -104.6 nT 4.66 500
270–280 s 10 s -103.6 nT 4.61 500
273–283 s 10 s -103.3 nT 4.60 500
232–242 s 10 s -102.6 nT 4.57 500
266–286 s 20 s -101.9 nT 4.53 1000
263–283 s 20 s -101.7 nT 4.52 1000

Files

Interpretation boundary